導 讀 反(fan)滲(shen)(shen)透膜(mo)(mo)(mo)元件(jian)一般情(qing)況(kuang)下(xia),可(ke)以(yi)使(shi)(shi)用2~3年(nian)左右。若想(xiang)延長(chang)使(shi)(shi)用壽(shou)命(ming),可(ke)對反(fan)滲(shen)(shen)透膜(mo)(mo)(mo)元件(jian)進(jin)行(xing)(xing)(xing)清洗(xi)(xi)(xi),通常分(fen)為物理(li)(li)沖(chong)(chong)(chong)(chong)洗(xi)(xi)(xi)和化(hua)(hua)學沖(chong)(chong)(chong)(chong)洗(xi)(xi)(xi)兩種方式(shi),當(dang)物理(li)(li)沖(chong)(chong)(chong)(chong)洗(xi)(xi)(xi)已經不能(neng)使(shi)(shi)反(fan)滲(shen)(shen)透膜(mo)(mo)(mo)的性(xing)(xing)能(neng)恢(hui)復(fu),就應該(gai)需進(jin)行(xing)(xing)(xing)化(hua)(hua)學清洗(xi)(xi)(xi)了。 反(fan)滲(shen)(shen)透膜(mo)(mo)(mo)元件(jian)一般情(qing)況(kuang)下(xia),可(ke)以(yi)使(shi)(shi)用2~3年(nian)左右。若想(xiang)延長(chang)使(shi)(shi)用壽(shou)命(ming),可(ke)對反(fan)滲(shen)(shen)透膜(mo)(mo)(mo)元件(jian)進(jin)行(xing)(xing)(xing)清洗(xi)(xi)(xi),通常分(fen)為物理(li)(li)沖(chong)(chong)(chong)(chong)洗(xi)(xi)(xi)和化(hua)(hua)學沖(chong)(chong)(chong)(chong)洗(xi)(xi)(xi)兩種方式(shi),當(dang)物理(li)(li)沖(chong)(chong)(chong)(chong)洗(xi)(xi)(xi)已經不能(neng)使(shi)(shi)反(fan)滲(shen)(shen)透膜(mo)(mo)(mo)的性(xing)(xing)能(neng)恢(hui)復(fu),就應該(gai)需進(jin)行(xing)(xing)(xing)化(hua)(hua)學清洗(xi)(xi)(xi)了。
根據經驗,如果反滲透裝置每隔三個月或更長時間清洗一次。如果是1-3個月清洗一次,則需要改進運行工況,提高預處理效果。 (1)標準化的淡水產量下降了10%以上。 (2)標準(zhun)化的透鹽率增(zeng)加(jia)了10%以上(shang)。 (3)為了維(wei)持正常的淡水流量,經溫度校準后給(gei)水與濃水間的壓差(cha)增加了10%以上。 (4)內部裝置(zhi)有嚴重(zhong)污染物和結垢物。 (5)RO裝置長期停用前。 (6)RO裝(zhuang)置例行維護。 判斷是否對反滲透系統實施清(qing)洗前,還應綜合(he)考慮以(yi)下一(yi)些可能產(chan)生上述現(xian)象的其他原因: ☆ 操作壓(ya)力下降(壓(ya)力控制裝置失靈和高(gao)壓(ya)泵出現異常); ☆ 進水溫度降低(di)(加熱(re)器(qi)故(gu)障(zhang),或季節變化引起水溫降低(di)); ☆ 進水含鹽量升高(gao); ☆ 預處理(li)異常; ☆ 膜損傷、串聯膜元件中(zhong)心管不對中(zhong)、壓力容(rong)器O型(xing)密封(feng)(feng)圈(quan)密封(feng)(feng)不嚴等原因導(dao)致濃水滲入(ru)淡(dan)水。 反(fan)滲透膜元件(jian)中常見的(de)污染物(wu)主(zhu)要有CaCO3、CaSO4、BaSO4、SrSO4、金屬氧化物(wu)、硅沉積(ji)物(wu)、有機物(wu)和生(sheng)物(wu)黏泥。當(dang)阻(zu)垢(gou)劑(ji)投加系統(tong)或(huo)加酸系統(tong)出現故障時,CaCO3有可能沉積(ji)在膜元件(jian)中,應采取化學清(qing)洗的(de)方法進行循環清(qing)洗或(huo)通(tong)宵浸泡。 不(bu)同(tong)污染物對膜造(zao)成(cheng)不(bu)同(tong)程度(du)的損害,不(bu)同(tong)污染物應用不(bu)同(tong)清洗(xi)液。 (1)反滲透清洗系統 一般由清洗泵(beng)、藥劑配制(zhi)箱、5-20um保安過濾器、加熱(re)器、相關管(guan)道閥門和控制(zhi)儀表等組成。 (2)操作 清(qing)(qing)洗(xi)(xi)方式有靜態浸(jin)(jin)泡(pao)和循環(huan)清(qing)(qing)洗(xi)(xi)等。靜態浸(jin)(jin)泡(pao)用清(qing)(qing)洗(xi)(xi)液(ye)浸(jin)(jin)泡(pao)膜(mo),時間視污(wu)染程度,大致為1-15h。循環(huan)清(qing)洗的一般(ban)步(bu)驟是: 用泵將淡水從藥劑配制箱送入壓力容器中,并排放幾(ji)分鐘。 在藥劑配制(zhi)箱中用(yong)淡水配制(zhi)清洗(xi)液(ye)。 用(yong)(yong)清(qing)(qing)(qing)(qing)(qing)洗液對壓(ya)(ya)力(li)容(rong)器(qi)循環清(qing)(qing)(qing)(qing)(qing)洗1h或(huo)達到預定(ding)時(shi)(shi)間(jian)。清(qing)(qing)(qing)(qing)(qing)洗流(liu)量(liang)可(ke)根據下表確定(ding),當污染嚴重(zhong)時(shi)(shi),清(qing)(qing)(qing)(qing)(qing)洗流(liu)量(liang)可(ke)提(ti)高到表中(zhong)樹脂(zhi)的(de)150%。這時(shi)(shi),清(qing)(qing)(qing)(qing)(qing)洗壓(ya)(ya)降(jiang)較大,一(yi)般控制不超(chao)過(0.10-0.14MPa)/根膜(mo)元件(jian)或(huo)0.4MPa/根膜(mo)組件(jian)。剛開始進(jin)藥清(qing)(qing)(qing)(qing)(qing)洗時(shi)(shi),可(ke)用(yong)(yong)表中(zhong)流(liu)量(liang)值(zhi)的(de)50%將已(yi)加熱(re)的(de)清(qing)(qing)(qing)(qing)(qing)洗液打入(ru)壓(ya)(ya)力(li)容(rong)器(qi)中(zhong),控制壓(ya)(ya)力(li),以既(ji)能(neng)夠克服進(jin)水到出水之間(jian)的(de)壓(ya)(ya)降(jiang)又沒有淡水流(liu)出為宜。為了避免清(qing)(qing)(qing)(qing)(qing)洗液被稀(xi)釋,可(ke)打開濃水排(pai)放閥門,先排(pai)出系統積水后(hou)再(zai)進(jin)行清(qing)(qing)(qing)(qing)(qing)洗。對反(fan)滲透(tou)系統可(ke)分(fen)段進(jin)行清(qing)(qing)(qing)(qing)(qing)洗。清(qing)(qing)(qing)(qing)(qing)洗方(fang)向與運行方(fang)向相同(tong),不允許反(fan)向清(qing)(qing)(qing)(qing)(qing)洗,否則可(ke)能(neng)引起膜(mo)卷凸出而損壞(huai)膜(mo)元件(jian)。 循環清(qing)洗(xi)(xi)完成后,再用淡水將藥(yao)劑配制箱洗(xi)(xi)干凈。 用淡水沖洗上述壓(ya)力(li)容器(qi)。 沖(chong)洗(xi)結束后(hou),在淡水排出(chu)閥打開(kai)狀態下運行反滲透系(xi)統,直到淡水清(qing)潔、無泡沫或無清(qing)洗(xi)液,通常需要(yao)15-30min的(de)時(shi)間。
反(fan)滲透(tou)設備在正(zheng)常運行一段時間后,反(fan)滲透(tou)膜元件會受到給水中可能存在的懸浮物或(huo)難溶鹽(yan)的污(wu)染,會出現以下癥狀: 是否需要更(geng)換反滲(shen)透膜元件,還是要根(gen)據實際情況而(er)定。